Object1200×800 mm granite plate
Grid5×4, 20 points, 4 closed loops
Instrument0.1″ autocollimator + 200 mm bridge
Closure4 μm maximum (height equivalent)
Why closure first
Closure comes from drift, bridge movement and recording, not the plate.
4 μm over 200 mm is about 4″, near the repeatability limit, so the run is usable.
Evaluation
Least-squares PV 9 μm, minimum zone 7 μm: passes the 8 μm minimum-zone requirement.
Report both values with the method.
Case workflow, animated
1 / 4
- Confirm the task and datum
- Lay out stations by span
- Acquire readings and convert
- Evaluate and verify
The animation follows the station layout and calculation order of this case. Values are teaching data.
ConclusionClosure 4 μm is credible; minimum zone 7 μm passes; least squares 9 μm is reference only.
Teaching example. Grade assessment follows the current standard.