MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / 1.2 m plate grid: what a 4 μm closure means
CASE 21 · TEACHING DATA

1.2 m plate grid: what a 4 μm closure means

Closure is the cheapest self-check in grid flatness: it does not prove the form, but it does show whether the run is trustworthy.

Object1200×800 mm granite plate
Grid5×4, 20 points, 4 closed loops
Instrument0.1″ autocollimator + 200 mm bridge
Closure4 μm maximum (height equivalent)
h_i = sum L tan(theta)

Why closure first

Closure comes from drift, bridge movement and recording, not the plate.

4 μm over 200 mm is about 4″, near the repeatability limit, so the run is usable.

Evaluation

Least-squares PV 9 μm, minimum zone 7 μm: passes the 8 μm minimum-zone requirement.

Report both values with the method.

Case workflow, animated

Minimum zone: two parallel planesLeast squares: minimal residual sumDifferent results — state the method in the reportSchematic · not to scale · not measured data
1 / 4
  1. Confirm the task and datum
  2. Lay out stations by span
  3. Acquire readings and convert
  4. Evaluate and verify

The animation follows the station layout and calculation order of this case. Values are teaching data.

ConclusionClosure 4 μm is credible; minimum zone 7 μm passes; least squares 9 μm is reference only.

Teaching example. Grade assessment follows the current standard.