Principle
Slope methods integrate connected lines; direct-height methods measure coordinates in a shared reference.
Preparation
Specify the measurement area, grid, support condition and evaluation method. Separate slope reconstruction from direct coordinate measurement.
Workflow diagram
Procedure
- Design a grid or closed measurement network with shared nodes and check paths.
- Stabilize the supports and temperature, clean the surface and define coordinates.
- Integrate slope readings along each line, or record direct point heights with an appropriate system.
- Bring all lines into a common height reference and inspect junction and closure discrepancies.
- Report the map, sampling layout, fitting method and limitations between measured points.
Calculation
After fitting z=ax+by+c, compute rᵢ=zᵢ−(axᵢ+byᵢ+c) and PV=max(rᵢ)−min(rᵢ). This is residual PV about that plane; minimum-zone evaluation is separate.
Illustrative example
Illustration: fitted residuals of +2 and −1 μm give a 3 μm PV about that plane, not automatically minimum-zone flatness.
Limitations
- Do not combine profiles that have each been independently reset to zero.
- Peak-to-valley residuals about a least-squares plane are not the minimum-zone flatness result.
- A sparse grid may miss local defects.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.