Why a grid
A single diagonal may pass over a local dip and give an optimistic result. A grid makes lines cross each other, and shared stations provide a closure check.
Nine points are only minimal coverage. For larger areas or tighter tolerances, densify the grid and state the unsampled regions in the report.
Setup and support
Support the plate on three points in the same way it is used, and do not move the supports during measurement. The bridge spans two adjacent stations with a constant 300 mm span.
Measure three transverse lines, then three longitudinal lines. Height differences at crossing stations check closure. Complete all lines in one temperature environment.
Readings and fitting
With the centre station as zero, the nine relative heights are 0, 1.2, 0.4 / 0.8, 2.0, 1.1 / 0.5, 1.5, 0.3 in μm.
The overall tilt is significant: the fitted plane slopes about 83 μm/m in X and 117 μm/m in Y. After removing tilt the residuals lie between −0.77 and +1.13 μm, a peak-to-valley of 1.9 μm.
Conclusion and cautions
1.9 μm is below the 3 μm requirement, so the plate passes. Tilt does not affect flatness, but it does affect how a workpiece sits, so mention levelling where relevant.
The minimum-zone value is usually not larger than the least-squares residual peak-to-valley. An acceptance report must name the algorithm, otherwise the two numbers cannot be compared.
Case workflow, animated
- Confirm the task and datum
- Lay out stations by span
- Acquire readings and convert
- Evaluate and verify
The animation follows the station layout and calculation order of this case. Values are teaching data.
Teaching data covering nine stations only. No conclusion is drawn for unsampled areas; real acceptance follows the agreed standard and sampling density.