MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / MC030-MCE200X2 · Multi-unit electronic autocollimator system
PRODUCT TECHNICAL SHEET

MC030-MCE200X2 · Multi-unit electronic autocollimator system

Multi-unit electronic autocollimator systems

MC030-MCE200X2
MC030-MCE200X2

Multi-unit electronic autocollimator system accuracy 0.5″

Select using tolerance, distance, references and environmental conditions.

PDF for reading, editable Word; generated from the same source data.

Product overview

The multi-unit electronic autocollimator system is intended for complex angular measurement systems and enables users to compare and analyse measurement data from several autocollimators.

Applications

One software package can control up to 8 or even 16 autocollimators. X and Y axes are measured simultaneously. Each instrument can be controlled individually or together. A high-resolution photoelectric detector is used. Internal and external light-source modes can be switched, and target patterns can be configured as a cross, dot or single line.

Specifications

Objective focal length200mm
Clear aperture48mm
Optical axis height78mm
Field of view (X, Y)3200*2400″
Resolution0.1″, 0.01″, 0.001″, 0.0001″ adjustable (arc sec. arcseconds )
Indication accuracy±100″≤ ±0.5″; ±1000″≤ ±1″
Repeatability≤ 0.2″
Centre wavelength625nm
Measurement frequency response≤ 30HZ(Hz TYP.)
Light source typeSemiconductor LED light source
CommunicationUSB2.0
Third-party communication interfaceRS-232
Display methodSoftware display on a standard PC
Power supplyIntegrated power supply
Instrument dimensions (L * W * H)288*125*115mm (one main unit)
Main unit weight3.3kg

Original source ↗ · 2026-11-14

Resolution is not accuracy. Preserve range conditions and confirm missing data with the engineering team.

MOTION DIAGRAM

How it works, animated

Four steps: where the light comes from, where it returns, how the reading appears.

Synchronisation hubH1H2H3H4Four heads read one datum: no re-stationingSchematic · not to scale · not measured data
1 / 4
  1. Optical path: source collimated by the objective
  2. The mirror returns the beam along its own path
  3. The image point moves; the detector reads the shift
  4. Convert with θ = x/2f

The animation shows the optical path and how a reading arises. It does not represent the resolution, range or accuracy of this model.

Where this instrument is used

Product and measurement standards

References to check for selection, specifications and methods. Listing does not certify this model or prove testing to a standard; confirm the edition and applicable clauses in the technical agreement.

Product standard reference

JB/T 8232-2024 · Autocollimators

Product-standard candidate; confirm model applicability and inspection records. No conformity claim.

Official directory ↗
Application method reference

GB/T 17421.1-2023 · Machine tool testing — No-load or quasi-static geometry

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

GB/T 1958-2017 · GPS — Geometrical tolerance inspection and verification

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

GB/T 18779.1-2022 · GPS inspection — Conformity decision rules

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 230-1:2012 · Machine tools — Geometric accuracy under no-load or quasi-static conditions

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO/TR 230-11:2018 · Measuring instruments for machine tool geometry tests

Instrument-selection technical report, not a manufacturing or product-certification standard.

Official directory ↗
Application method reference

ISO 12780-1:2011 · Straightness — Vocabulary and parameters

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 12781-1:2011 · Flatness — Vocabulary and parameters

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 14253-1:2017 · GPS — Conformity decision rules

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗

GB/ISO entries mainly reference application methods. JB/T 8232-2024 is a product-standard candidate; model applicability and inspection records require confirmation. No conformity claim is made.