MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Sampling, filtering and jitter: when averaging helps and when it lies
PRINCIPLE NOTE

Sampling, filtering and jitter: when averaging helps and when it lies

A jumping reading is not necessarily a fault. Too low a sampling rate folds fast disturbances into slow wander; too much averaging erases real steps. Both make a report look cleaner than reality.

repeatspanmirrorangleu_c = sqrt(sum u_i^2)
f_s ≥ 2.5·f_max; averaging N samples divides noise by √N (0.6″ → 0.15″, N=16)

Animated explanation

As temperature rises, zero and sensitivity driftPaired runs separate driftTimeSchematic · not to scale · not measured data
1 / 4
  1. Establish the geometry
  2. See how one reading forms
  3. Change a condition and observe
  4. Return to the formula and its limits

The animation explains relationships and directions. Read numbers from the formula, the standard and your records.

Noise or signal first

Twenty readings at one position: symmetric scatter means noise, monotonic drift means thermal or mechanical settling, isolated spikes point to supply, grounding or source.

Do not filter before you know which one you have.

Averaging pays by the square root

0.6″ random noise falls to 0.15″ with 16 averages, at 16× the time cost, during which drift enters.

For slow processes, long averaging averages away real change; use medians or piecewise fits.

Keep the raw data

Reports may show averages, but keep the raw series: only raw data settles a dispute.

Related methods and industries

Recommended instruments