MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Sectioned Splicing Measurement of Long Guideways
MEASUREMENT METHOD

Sectioned Splicing Measurement of Long Guideways

When a guideway exceeds the effective reach of a single autocollimator station or the return light degrades, sectioned splicing yields the full straightness profile. It suits long beds and large platforms beyond single-section capability, feeding acceptance evaluation and error compensation.

Principle

The guideway is divided into sections with an overlap zone of several stations between neighbours. Each section is integrated by the standard autocollimation method; in the overlap, the tail of one section and the head of the next sample the same stations. Splicing shifts the later section by a constant (optionally with a small rotation) minimising the height mismatch in the overlap, applied successively to build the unified profile. Rotational correction must be used cautiously, only with a sufficiently long overlap and clear justification.

Preparation

Plan the sections: each within the autocollimator's effective reach, with at least 2–3 overlap stations (recommended teaching value). Number the whole line uniformly so overlap stations coincide between sections. Re-set the instrument per section and check return light; keep temperatures as uniform as possible and record them. Maintain one span across all sections.

Workflow diagram

01Plan sections and overlaps02Measure and integrate each03Compute overlap mismatch04Shift and splice05Report full profile06Check residuals and report

Procedure

  1. Fix section lengths, overlap positions and station numbering on a whole-line layout.
  2. Set up on the first section, measure and integrate, recording overlap heights.
  3. Move to the second section, align independently and integrate; overlap stations coincide with the first section.
  4. Compute the systematic height offset between the two sections in the overlap (mean or least-squares constant).
  5. Shift the second section by that offset and join; proceed through all sections.
  6. Check overlap residuals and report the unified profile evaluated against the agreed reference, with measurement and splicing details.

Calculation

In-section integration follows straightness: Δh=L·tan(θ″·π/648000). The splicing constant is d=mean(zA,k−zB,k) over overlap stations, giving zB,k′=zB,k+d. With rotation: zB,k′=zB,k+d+g·(xk−x0), g from a least-squares fit of the overlap, used only when justified. The overlap residual standard deviation assesses splice quality and feeds the uncertainty budget.

Illustrative example

Schematic · not measured data
Schematic: two sections spliced through the overlap into one profile; values illustrative.

Teaching data, not measured: an 8 m guideway split into two 5 m sections with a 3-station overlap. Section one reads [1.2, 1.4, 1.1] μm and section two [0.6, 0.8, 0.5] μm at the same stations; the splice constant is d=+0.6 μm with zero residual in this rounded demonstration. Real residuals are non-zero and must be assessed statistically. No real guideway is implied.

Limitations

  • Inconsistent overlap station positions mix layout error into the splice constant.
  • Indiscriminate rotational splicing amplifies far-end error; consider it only when a constant shift is insufficient.
  • Overlooking instrument re-setting error between sections, absorbed into the measured profile.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

Method reference ↗ Method reference ↗ 
STEP BY STEP

Understand the measurement step by step

Principle schematic · not to scale
1 / 6
  1. The 9 m guideway in full view with the four segments in different colours and the shared stations blinking.
  2. Segment A runs its three steps and the height polyline climbs to about 16 μm.
  3. Segment B is set up anew and its polyline is shifted to the shared station of A.
  4. C and D join in turn and the closure values are labelled at the seams.
  5. The ten unified heights form one profile and the end-point line is drawn.
  6. The residual curve is labelled 21.4 μm and 2.4 μm/m.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Spliced measurement of a 9000 mm gantry machine guideway

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

A 9000 mm-travel gantry machine has a guideway longer than one measurement setup, so it is measured in four segments and spliced. Each segment covers 3000 mm (three 1000 mm steps) and shares one station with its neighbour, whose height difference provides the constant shift. The autocollimator is re-set per segment, the reflector base span is 1000 mm, and each segment is integrated conventionally.

Setup and preparation

  • Mark a station every 1000 mm from 0 to 9000 mm and fix the starts of segments A (0–3000), B (2000–5000), C (4000–7000) and D (6000–9000) plus their shared stations.

  • Set the autocollimator at one end of the guideway with the axis parallel, then measure and integrate the three steps of segment A.

  • Move the instrument to 2000 mm for segment B and measure independently, keeping the shared stations at 2000 and 3000 mm in exactly the same positions.

  • Shift segment B by the height difference at the shared station so that it joins A, then treat C and D the same way.

  • Compute the closure at every joint (the same station measured in two segments) and confirm the spliced profile is continuous.

  • Record 21.2 °C; all four segments are measured in one shift with no support adjustment.

Example data and records

  • Segment A, step 1 (0→1000 mm): +1.80″

  • Segment A, step 2 (1000→2000 mm): +1.20″

  • Segment A, step 3 (2000→3000 mm): +0.40″

  • Segment B, step 1 (2000→3000 mm): +0.60″

  • Segment B, step 2 (3000→4000 mm): -0.40″

  • Segment B, step 3 (4000→5000 mm): -1.10″

  • Segment C, step 1 (4000→5000 mm): -1.40″

  • Segment C, step 2 (5000→6000 mm): -1.90″

  • Segment C, step 3 (6000→7000 mm): -1.20″

  • Segment D, step 1 (6000→7000 mm): -0.70″

  • Segment D, step 2 (7000→8000 mm): -0.20″

  • Segment D, step 3 (8000→9000 mm): +0.70″

  • Each joint overlaps one station: A/B at 3000 mm, B/C at 5000 mm, C/D at 7000 mm, closures +0.97 → -1.45 → +2.42 μm

  • 21.2 °C; all four segments measured in one shift without re-adjusting the supports

Calculation steps

Scale factor k=1000×π/648000×1000=4.848 μm per arcsec. Segment A accumulates +0.00 → +8.73 → +14.54 → +16.48 μm; segment B accumulates +0.00 → +2.91 → +0.97 → -4.36 μm locally and +14.54 → +17.45 → +15.51 → +10.18 μm after a shift of +14.54 μm at 2000 mm; C shifts by +15.51 μm to +15.51 → +8.73 → -0.48 → -6.30 μm and D by -0.48 μm to -0.48 → -3.88 → -4.85 → -1.45 μm. The joint closures are +0.97 → -1.45 → +2.42 μm, at most 2.42 μm, so the zero and scale of each segment agree. Averaging the shared stations gives 10 unified heights +0.00 → +8.73 → +14.54 → +16.97 → +15.51 → +9.45 → -0.48 → -5.09 → -4.85 → -1.45 μm. Against the end-point line the end-to-end rise is -1.45 μm, each station is corrected by -0.16 μm, the residuals are +0.00 → +8.89 → +14.87 → +17.45 → +16.16 → +10.26 → +0.48 → -3.96 → -3.56 → +0.00 μm and the straightness is 21.41 μm.

Interpretation

Spliced straightness over the full 9000 mm is 21.4 μm (2.4 μm/m). This passes the 0.03 mm full-length tolerance with 8.6 μm margin, and the largest joint closure of 2.42 μm is inside the 2 μm splicing limit.

Verification and pitfalls

  • Joint closure is the only quality evidence for splicing: 2.42 μm here, and above 2 μm the shared stations were not truly coincident.

  • Only shift segments; never rotate one to absorb a closure, because rotation fabricates a bend across the joint.

  • Re-setting the instrument changes the angle between the axis and the guideway, which integrates into a tilt; a shift removes the constant term but not a slope change.

  • An overlap of at least two stations checks both zero and slope; with one shared station, as here, the slope difference appears in the closure.

  • Keep the supports unchanged across all four segments; any shim adjustment means re-measuring that segment.