Principle
The guideway is divided into sections with an overlap zone of several stations between neighbours. Each section is integrated by the standard autocollimation method; in the overlap, the tail of one section and the head of the next sample the same stations. Splicing shifts the later section by a constant (optionally with a small rotation) minimising the height mismatch in the overlap, applied successively to build the unified profile. Rotational correction must be used cautiously, only with a sufficiently long overlap and clear justification.
Preparation
Plan the sections: each within the autocollimator's effective reach, with at least 2–3 overlap stations (recommended teaching value). Number the whole line uniformly so overlap stations coincide between sections. Re-set the instrument per section and check return light; keep temperatures as uniform as possible and record them. Maintain one span across all sections.
Workflow diagram
Procedure
- Fix section lengths, overlap positions and station numbering on a whole-line layout.
- Set up on the first section, measure and integrate, recording overlap heights.
- Move to the second section, align independently and integrate; overlap stations coincide with the first section.
- Compute the systematic height offset between the two sections in the overlap (mean or least-squares constant).
- Shift the second section by that offset and join; proceed through all sections.
- Check overlap residuals and report the unified profile evaluated against the agreed reference, with measurement and splicing details.
Calculation
In-section integration follows straightness: Δh=L·tan(θ″·π/648000). The splicing constant is d=mean(zA,k−zB,k) over overlap stations, giving zB,k′=zB,k+d. With rotation: zB,k′=zB,k+d+g·(xk−x0), g from a least-squares fit of the overlap, used only when justified. The overlap residual standard deviation assesses splice quality and feeds the uncertainty budget.
Illustrative example
Teaching data, not measured: an 8 m guideway split into two 5 m sections with a 3-station overlap. Section one reads [1.2, 1.4, 1.1] μm and section two [0.6, 0.8, 0.5] μm at the same stations; the splice constant is d=+0.6 μm with zero residual in this rounded demonstration. Real residuals are non-zero and must be assessed statistically. No real guideway is implied.
Limitations
- Inconsistent overlap station positions mix layout error into the splice constant.
- Indiscriminate rotational splicing amplifies far-end error; consider it only when a constant shift is insufficient.
- Overlooking instrument re-setting error between sections, absorbed into the measured profile.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.