Principle
A collimator telescope sights a concentric target such as a glass target with a centred pattern; the offset between the reticle cross-line and the target centre converts to lateral displacement through the objective imaging relation. The datum line joins the targets at two reference points, analogous to an endpoint reference, and offsets of intermediate targets give their position deviations. In autocollimation mode a mirror in front of the objective also yields its tilt about the optical axis, so position and angle are measured simultaneously.
Preparation
Check the telescope's focus-induced line-of-sight error over the working distance and correct per the manual if needed. Match targets and mounts to the bores or datums and verify the centring of target versus mount rotation axis. Set the two reference points rigidly so they do not move mid-measurement, and record the thermal environment.
Workflow diagram
Procedure
- Mount targets at the two reference points, install the telescope and roughly align the sight line through both datum targets.
- Focus stepwise to each working distance and record focus-induced sight-line shifts.
- Define the datum by zeroing on the two datum targets (endpoint convention) and read the offsets of intermediate targets from the cross-line.
- Convert offsets to linear deviations with the imaging scale, separately in the horizontal and vertical directions.
- Where angular data are needed, read the mirror tilt to the sight line in autocollimation mode.
- Assemble position deviations and angles, and report the datum definition, environment and uncertainty.
Calculation
Target offset conversion: Δ=K·d, where d is the micrometer reading difference and K the conversion factor at that distance from the manual or calibration. Deviations follow the endpoint rule: ei=Δi−[Δ1+(Δn−Δ1)·(xi−x1)/(xn−x1)]. Angular readings convert as in autocollimation: θrad=θ″·π/648000.
Illustrative example
Teaching data, not measured: two datum bores 2 m apart with a measured bore at 1 m. With both datum targets reading zero, the intermediate target converts to +0.03 mm horizontally, i.e. a +0.03 mm horizontal deviation from the datum line. The numbers only illustrate the conversion, not any instrument performance.
Limitations
- Unverified focus error bends the sight line and biases readings at different distances.
- Eccentricity between target centre and mount rotation axis introduces an offset.
- Datum points displaced by force or temperature mid-measurement invalidate the whole line.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.