Set-up and readings
Magnetic bases on both sides of the disc, span 1200 mm, three readings per station.
The mean difference is 6.2″ with 0.8″ range, so the data are usable.
Angle to height
Δh = 1200 × tan(6.2″) = 0.036 mm.
Use the station spacing, not the disc diameter; state the span used or the number cannot be reproduced.
Decision
0.036 mm passes 0.05 mm with about 28% margin. If a whole batch sits near the limit, check turning set-up, not individual discs.
Case workflow, animated
- Confirm the task and datum
- Lay out stations by span
- Acquire readings and convert
- Evaluate and verify
The animation follows the station layout and calculation order of this case. Values are teaching data.
Teaching data. Acceptance follows railway standards and OEM conditions, including runout and thickness variation.