Principle
Parallelism requires a common direction or datum plane; independently removing tilt discards needed information.
Preparation
Identify the datum and measured feature, corresponding stations, reference transfer and support conditions.
Workflow diagram
Procedure
- Establish one reference direction and mark corresponding measurement locations.
- Measure the datum side and retain both direction and form without arbitrary re-zeroing.
- Transfer the optical or mechanical reference and measure the second side using the same coordinate convention.
- Evaluate the directional difference, corresponding-point variation or datum-constrained surface zone as appropriate.
- Repeat with the measurement order reversed and record adjustments and final verification.
Calculation
For two mean directions, δ=α₂−α₁ and e≈Lδrad. The angle between fitted directions does not replace a complete surface tolerance-zone evaluation.
Illustrative example
Illustration: directions differing by 1″ in a shared reference correspond to about 0.97 μm over 200 mm.
Limitations
- Two individually straight guideways are not necessarily parallel.
- The angle between fitted plane normals is not a universal substitute for surface parallelism.
- Reference transfer and changing supports can conceal real deviations.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.