Level and face inspection plan for a vertical lathe table
For the installation level and face flatness of a vertical lathe circular table (Ø1600 mm, example/teaching data). The autocollimator measures radial generatrices through the centre; an electronic level cross-checks the overall tilt in two orthogonal directions. Lines are tied to a common datum at the centre to evaluate flatness and derive the levelling correction.
Instruments
- Photoelectric autocollimator (0.1″ class) with 200 mm reflector base (example)
- Calibrated electronic level
- Centring and station marking tools
- Temperature logger
Procedure
- Confirm the Ø1600 mm table (example), rotary support and clamping state, the layout of 4 radial lines through the centre and the evaluation agreement.
- Clean the table; lay out nodes at a 200 mm span along each radial line from rim through centre to the opposite rim.
- Read each line with the autocollimator; measure the overall tilt with the electronic level in two orthogonal directions.
- Tie the radial lines at the centre node and integrate via Δh=L·tanθ into generatrix profiles.
- Fit a least-squares plane for tilt magnitude and azimuth and cross-check against the electronic level.
- Rotate the table 180° and repeat one generatrix to separate spindle rotation error from table error.
- Deliver generatrix profiles, tilt magnitude and azimuth, the cross-check log and levelling shim advice.
Calculation
Δh=L·tanθ; with L=200 mm, 1″≈0.970 μm (example/teaching data). The centre node height is the mean over radial lines. Tilt follows from the least-squares plane normal, α≈arctan(Δh/D), with D the diameter.
Reporting
- Rotary support and clamping state recorded
- Centre-node closure checked
- Tilt difference between instruments within the agreed limit
Limitations
Does not assess table runout or spindle rotation accuracy; high-frequency local waviness between spans is outside the resolution of this plan. Adjustment conclusions apply to the support and temperature state at measurement.
Understand the measurement step by step
- 01
Confirm the Ø1600 mm table (example), rotary support and clamping state, the layout of 4 radial lines through the centre and the evaluation agreement.
- 02
Clean the table; lay out nodes at a 200 mm span along each radial line from rim through centre to the opposite rim.
- 03
Read each line with the autocollimator; measure the overall tilt with the electronic level in two orthogonal directions.
- 04
Tie the radial lines at the centre node and integrate via Δh=L·tanθ into generatrix profiles.
- 05
Fit a least-squares plane for tilt magnitude and azimuth and cross-check against the electronic level.
- 06
Rotate the table 180° and repeat one generatrix to separate spindle rotation error from table error.
- 07
Deliver generatrix profiles, tilt magnitude and azimuth, the cross-check log and levelling shim advice.
- Stop & clean · Table stopped and cleaned, free of swarf.
- Radial setup · The 200 mm bridge steps along one radius.
- Read per step · The electronic level logs each segment tilt.
- Convert heights · Tilt converts into micrometre segment heights.
- Level evaluation · Cumulative heights give the radial level result.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Vertical Lathe Table Level and Face Inspection · Tutorial Case
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: radial segmented level measurement of a vertical lathe circular table face; data are instructional settings.
Setup and preparation
Stop the table and clean the face
Place an electronic level on a 200 mm bridge along one radius
Step outward from the table centre along the radius, reading each segment
Take two readings per segment and average
Compute segment heights and cumulative deviation
Example data and records
Bridge span L=200 mm; segment 1 electronic level reading θ₁=-0.4″
Segment 2 electronic level reading θ₂=+0.6″
Segment 3 electronic level reading θ₃=-0.2″
Calculation steps
Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 200×tan(-0.4″)=-0.39 μm; Segment 2: 200×tan(+0.6″)=+0.58 μm; Segment 3: 200×tan(-0.2″)=-0.19 μm. Cumulative heights: 0→-0.39→+0.19→+0.00 μm; peak-to-valley PV=+0.19−(-0.39)=+0.58 μm.
Interpretation
Tutorial result PV≈0.58 μm, demonstrating micrometre-level evaluation of the radial level of the vertical lathe face.
Verification and pitfalls
Bridge spans clear of T-slots; use a spanning insert if needed
Let the level thermally settle before reading
Measure along the radius and its reverse for cross-check