Perpendicularity inspection plan for a rolling mill housing window
For perpendicularity of the two column faces of a rolling mill housing window (4000 mm window height, example/teaching data) to its base, and the relative angle (gap taper) between the column faces. A pentaprism folds the vertical measuring line into the horizontal autocollimator path; the base reference line is measured first, then the column face station by station.
Instruments
- Photoelectric autocollimator (0.1″ class)
- Pentaprism with vertical slide carriage (90° fold verified, example)
- 250 mm span reflector/prism base
- Stable stands, station markers and temperature logger
Procedure
- Confirm the 4000 mm window height (example), datum selection (machined base) and perpendicularity evaluation agreement.
- Establish a horizontal reference line on the base and measure its straightness with the autocollimator as the perpendicularity datum.
- Move the pentaprism up the column face in 250 mm steps and read the autocollimator to 0.1″ at each station.
- Measure both column faces and integrate via Δh=L·tanθ into tilt curves relative to the datum.
- Reverse-repeat once to verify pentaprism folding and carriage repositioning stability.
- Convert to full-height perpendicularity and the relative angle between the two column faces (window taper).
- Deliver datum-line data, column tilt curves, perpendicularity and taper evaluation plus grinding/adjustment advice.
Calculation
Perpendicularity is the end-to-end lateral offset Δ=ΣL·tanθi over the full height; window taper is the algebraic combination of the two column tilt curves. With L=250 mm, 1″≈1.212 μm (example/teaching data). The pentaprism 90° fold error must be verified first and treated as a systematic term.
Reporting
- Pentaprism 90° fold angle verified
- Base reference line straightness measured first
- Reverse-run difference and carriage repeatability recorded
Limitations
Excludes elastic housing deformation under rolling load and local high spots on the window faces (contact measurement required). Assembly mismatch of multi-piece housings is outside this plan.
Understand the measurement step by step
- 01
Confirm the 4000 mm window height (example), datum selection (machined base) and perpendicularity evaluation agreement.
- 02
Establish a horizontal reference line on the base and measure its straightness with the autocollimator as the perpendicularity datum.
- 03
Move the pentaprism up the column face in 250 mm steps and read the autocollimator to 0.1″ at each station.
- 04
Measure both column faces and integrate via Δh=L·tanθ into tilt curves relative to the datum.
- 05
Reverse-repeat once to verify pentaprism folding and carriage repositioning stability.
- 06
Convert to full-height perpendicularity and the relative angle between the two column faces (window taper).
- 07
Deliver datum-line data, column tilt curves, perpendicularity and taper evaluation plus grinding/adjustment advice.
- Clean window · Window rail faces of the model cleaned.
- Vertical axis · Optical axis set vertically onto the window face.
- Step upward · The 250 mm bridge climbs the window face.
- Log readings · Pitch values recorded per segment.
- Perpendicularity · Cumulative conversion yields window perpendicularity.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Rolling Mill Housing Window Perpendicularity Inspection · Tutorial Case
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: segmented angular survey of a rolling mill housing window face for perpendicularity; data are instructional settings.
Setup and preparation
Clean the window faces of the mill housing teaching model
Place the autocollimator on a stand below the window, optical axis vertical onto the window rail face
Step a 250 mm bridge upward along the window face
Record the pitch reading per segment
Cumulate and convert for perpendicularity results
Example data and records
Bridge span L=250 mm; segment 1 autocollimator reading θ₁=+0.8″
Segment 2 autocollimator reading θ₂=-1.2″
Segment 3 autocollimator reading θ₃=+1.5″
Calculation steps
Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 250×tan(+0.8″)=+0.97 μm; Segment 2: 250×tan(-1.2″)=-1.45 μm; Segment 3: 250×tan(+1.5″)=+1.82 μm. Cumulative heights: 0→+0.97→-0.48→+1.34 μm; peak-to-valley PV=+1.34−(-0.48)=+1.82 μm.
Interpretation
Tutorial result PV≈1.82 μm, demonstrating the geometric inspection workflow for the mill housing window.
Verification and pitfalls
Bridge seats firmly on the window rail face
No vibration or displacement of the model during readings
Survey both window faces separately as cross-check