Parallelism inspection plan for injection moulding machine platens
For parallelism of the fixed and moving platens of an injection moulding machine in the clamped state (900×900 mm clamping face, example/teaching data). In the open state, measure each platen face flatness on a grid; under low-pressure clamping, evaluate parallelism from the four-corner gap difference. Fix the clamping force level and repeat clamping three times.
Instruments
- Photoelectric autocollimator (0.1″ class) with 150 mm reflector base (example)
- Four equal-length gap sensors or dial indicators for corner gaps
- Clamping force level confirmation and logging tools
- Temperature logger
Procedure
- Confirm the 900×900 mm platens (example), measurement grid, clamping force level (low-pressure clamping, example) and evaluation agreement.
- In the open state, measure the flatness of the fixed and moving platen faces on a 150 mm grid and tie each to its datum.
- Fit four equal-length gap sensors or dial indicators at the corners and record the corner gap differences under low-pressure clamping.
- Convert to the angle between the two faces and the clamped-state parallelism.
- Unclamp and reclamp three times; average and record the scatter.
- If needed, adjust tie-bar nut preload, re-measure and keep the before/after comparison.
- Deliver both-face data, clamped parallelism, repeatability records and adjustment notes.
Calculation
Parallelism angle α≈arctan(Δg/D), with Δg the diagonal gap difference and D the corner spacing; single-face flatness is the peak-to-valley after tying the grid to its datum. With D=900 mm, 1″≈4.36 μm gap equivalent (example/teaching data).
Reporting
- Clamping force level identical across runs
- Scatter of three clamping repeats recorded
- Before/after tie-bar adjustment versions kept in pairs
Limitations
Low-pressure clamping results do not represent platen deformation at rated clamping force; hot-state mould deformation needs re-measurement at operating temperature. Clamping-unit stiffness and part quality are not assessed.
Understand the measurement step by step
- 01
Confirm the 900×900 mm platens (example), measurement grid, clamping force level (low-pressure clamping, example) and evaluation agreement.
- 02
In the open state, measure the flatness of the fixed and moving platen faces on a 150 mm grid and tie each to its datum.
- 03
Fit four equal-length gap sensors or dial indicators at the corners and record the corner gap differences under low-pressure clamping.
- 04
Convert to the angle between the two faces and the clamped-state parallelism.
- 05
Unclamp and reclamp three times; average and record the scatter.
- 06
If needed, adjust tie-bar nut preload, re-measure and keep the before/after comparison.
- 07
Deliver both-face data, clamped parallelism, repeatability records and adjustment notes.
- State check · Clamping unit free, faces cleaned.
- Axis set · Optical axis parallel to the tie bars.
- Horizontal steps · The 200 mm bridge traverses the platen face.
- Read angles · Angular values read and logged.
- Parallelism check · Cumulative conversion yields the parallelism component.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Injection Moulding Platen Parallelism Inspection · Tutorial Case
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: segmented angular measurement preceding parallelism inspection of fixed and moving platens; data are instructional settings.
Setup and preparation
Clamping unit in free state, platen faces cleaned
Autocollimator on a stand beside the moving platen, optical axis parallel to the tie bars
Move a 200 mm bridge horizontally across the platen face step by step
Record the angular reading per segment
Cumulate three segments to convert the parallelism component
Example data and records
Bridge span L=200 mm; segment 1 autocollimator reading θ₁=+1.5″
Segment 2 autocollimator reading θ₂=-1″
Segment 3 autocollimator reading θ₃=+1.5″
Calculation steps
Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 200×tan(+1.5″)=+1.45 μm; Segment 2: 200×tan(-1″)=-0.97 μm; Segment 3: 200×tan(+1.5″)=+1.45 μm. Cumulative heights: 0→+1.45→+0.48→+1.93 μm; peak-to-valley PV=+1.93−(+0.00)=+1.93 μm.
Interpretation
Tutorial result PV≈1.93 μm, demonstrating segmented evaluation of platen parallelism.
Verification and pitfalls
Tie bar pretension states are uniform
Bridge avoids mould mounting holes
Survey all four generatrices (top/bottom/left/right) for cross-check