Granite plate grid flatness
Flatness of surface plates, machine tables and large bases, including grid design, closure checks and before/after lapping.
Instruments
- Autocollimator and bridge
- Electronic level for fast screening
- Equal-height blocks, temperature log
Procedure
- Design the grid and closed paths; define support points.
- Stabilise the plate thermally and set it on three or four supports.
- Measure line by line on a common height datum and check closure.
- Evaluate by least squares and minimum zone separately, stating which applies.
- Re-measure the same grid after lapping and report the difference map.
Calculation
Δh = L·tanθ between nodes; closure beyond the threshold means re-measure the path.
Reporting
- Support matches service
- Closure recorded
- Evaluation method stated
- Same grid before/after
Limitations
A sparse grid misses local defects; flatness does not cover hardness or roughness.
Understand the measurement step by step
- 01
Design the grid and closed paths; define support points.
- 02
Stabilise the plate thermally and set it on three or four supports.
- 03
Measure line by line on a common height datum and check closure.
- 04
Evaluate by least squares and minimum zone separately, stating which applies.
- 05
Re-measure the same grid after lapping and report the difference map.
- Step 1 · Design the grid and closed paths; define support points.
- Step 2 · Stabilise the plate thermally and set it on three or four supports.
- Step 3 · Measure line by line on a common height datum and check closure.
- Step 4 · Evaluate by least squares and minimum zone separately, stating which applies.
- Step 5 · Re-measure the same grid after lapping and report the difference map.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Worked nine-point grid flatness example on an 800×800 mm plate
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching example: nine nodes on a 400 mm grid over 800×800 mm; a least-squares plane is removed and the residual range is reported as flatness. Synthetic data.
Setup and preparation
Design the grid and closed paths; define support points.
Stabilise the plate thermally and set it on three or four supports.
Measure line by line on a common height datum and check closure.
Evaluate by least squares and minimum zone separately, stating which applies.
Example data and records
Node heights in µm: +0, +1, +2, +0, +1, +3, -1, +0, +2 in 3×3 row order.
Fitted plane slopes a = −0.00083, b = 0.00333 µm/mm.
Residuals in µm: 0.111, −0.222, −0.556, 0.444, 0.111, 0.778, −0.222, −0.556, 0.111.
Calculation steps
Least-squares plane z = z̄ + a(y−ȳ) + b(x−x̄); residual range = 1.333 µm. A coarse grid misses local waviness between nodes.
Interpretation
Flatness is about 1.333 µm with a high lower-right corner. Nine points only indicate a trend; formal acceptance needs the diagonal method and the specified point density.
Verification and pitfalls
Cover corners and edges; that is where deviation peaks.
Measure on the specified free supports; shimming hides the true form.
Log temperature and scan direction; granite anisotropy is small but not zero.