MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Gantry dual-drive synchronisation and beam geometry
DOWNLOADABLE MEASUREMENT PLAN

Gantry dual-drive synchronisation and beam geometry

Combined check of synchronisation error, beam deflection and rail parallelism for large machine tools, cutters and additive systems.

Instruments

Procedure

Calculation

Error = side difference; beam tilt = difference / span. Geometric and servo terms must be measured separately.

Reporting

Limitations

Synchronisation varies with speed and acceleration; static geometry does not prove dynamic performance.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Confirm control mode, synchronisation tolerance and travel.

  2. 02

    Place stations on both columns and the beam; record unloaded and loaded states.

  3. 03

    Run at low and working speed, acquiring side-to-side difference and beam angle.

  4. 04

    Separate geometric mismatch (rail parallelism) from control mismatch (gain, feed-forward).

  5. 05

    Re-measure the same points and report the synchronisation curve.

Principle schematic · not to scale
1 / 5
  1. Step 1 · Confirm control mode, synchronisation tolerance and travel.
  2. Step 2 · Place stations on both columns and the beam; record unloaded and loaded states.
  3. Step 3 · Run at low and working speed, acquiring side-to-side difference and beam angle.
  4. Step 4 · Separate geometric mismatch (rail parallelism) from control mismatch (gain, feed-forward).
  5. Step 5 · Re-measure the same points and report the synchronisation curve.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Worked dual-drive synchronisation example over 1500 mm

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching example: a gantry with a 1500 mm span shows a 45 µm side-to-side position difference, converted to beam tilt; geometry and servo error are separated.

Setup and preparation

  • Confirm control mode, synchronisation tolerance and travel.

  • Place stations on both columns and the beam; record unloaded and loaded states.

  • Run at low and working speed, acquiring side-to-side difference and beam angle.

  • Separate geometric mismatch (rail parallelism) from control mismatch (gain, feed-forward).

Example data and records

  • Steady side difference 45 µm, not transient jitter.

  • Tilt 6186.09″, i.e. 45 µm over 1500 mm.

  • Measure once with drives disabled and once while feeding to separate causes.

Calculation steps

θ = arctan(45/1500) = 6186.09″. Present statically it is mechanical; only dynamic means gain or following error.

Interpretation

A tilt of 6186.09″ produces squareness error of the same order on the workpiece.

Verification and pitfalls

  • Sample synchronisation at both ends and the middle, not at one point.

  • Beam sag adds to synchronisation error; measure them separately.

  • Log whether servo parameters changed; never mix before/after data.