MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Alignment inspection plan for a boring headstock vertical traverse
DOWNLOADABLE MEASUREMENT PLAN

Alignment inspection plan for a boring headstock vertical traverse

For the alignment of a floor/horizontal boring machine headstock traversing the column (1500 mm travel, example/teaching data) relative to the spindle axis. A test mandrel with an end-face mirror establishes the spindle axis datum; the autocollimator reads two-axis angular deviation over the full traverse, which is integrated into an axis-offset curve. Bidirectional measurement with averaging separates stick-slip and backlash effects.

Instruments

Procedure

Calculation

Each station angle θi is the axis tilt; transverse offset δ=ΣL·tanθi; the traverse squareness error is the algebraic difference of the end angles. With L=150 mm, 1″≈0.727 μm offset equivalent (example/teaching data).

Reporting

Limitations

Excludes spindle rotation accuracy, thermal growth and droop under long overhang tool loads. Conclusions apply only to the load and temperature state at measurement and do not replace boring trial-cut acceptance.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Confirm the 1500 mm traverse (example), 150 mm station spacing, datum-axis establishment and evaluation agreement.

  2. 02

    Fit the test mandrel in the spindle bore and mount the mirror on its end face; verify mandrel runout, then establish the spindle axis datum.

  3. 03

    Fix the autocollimator on the table, aim at the mirror and check the return beam over full travel.

  4. 04

    Stop every 150 mm on the upward traverse; after settling, read pitch and yaw to 0.1″.

  5. 05

    Repeat at the same stations on the downward traverse; average both directions and log the differences to separate stick-slip and backlash.

  6. 06

    Integrate the angular deviations via Δδ=L·tanθ into a transverse axis-offset curve and evaluate alignment jointly with column-verticality data.

  7. 07

    Deliver the angle table, offset curve, bidirectional comparison and wedge/counterweight adjustment advice.

Principle schematic · not to scale
1 / 5
  1. Clean datum · Clean the column guide and inspect its surface.
  2. Set optical axis · The optical axis is set vertically along the guide.
  3. Step upward · The 100 mm magnetic bridge climbs three steps.
  4. Read angles · Pitch angles are read and logged per step.
  5. Compute deviation · Convert and cumulate heights for travel error.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Boring Machine Headstock Alignment Inspection · Tutorial Case

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: segmented geometry measurement along the column guide during headstock travel on a boring machine; data are instructional settings.

Setup and preparation

  • Clean the column guide face and check for damage

  • Fix the autocollimator on the table with the optical axis vertical along the guide

  • Step a 100 mm magnetic bridge with reflector upward along the guide

  • Record the pitch reading of each segment

  • Cumulate three segments to evaluate guide straightness

Example data and records

  • Bridge span L=100 mm; segment 1 autocollimator reading θ₁=+2″

  • Segment 2 autocollimator reading θ₂=+1″

  • Segment 3 autocollimator reading θ₃=-1.5″

Calculation steps

Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 100×tan(+2″)=+0.97 μm; Segment 2: 100×tan(+1″)=+0.48 μm; Segment 3: 100×tan(-1.5″)=-0.73 μm. Cumulative heights: 0→+0.97→+1.45→+0.72 μm; peak-to-valley PV=+1.45−(+0.00)=+1.45 μm.

Interpretation

Tutorial result PV≈1.45 μm, demonstrating the evaluation of headstock travel geometry error.

Verification and pitfalls

  • Magnetic base securely attached with fall protection

  • Repeat reading difference per segment within 0.2″

  • Instrument stand isolated from floor vibration