Principle
The autocollimator records the tilt sequence of the reflector base along every line, and each line is integrated into a height profile. A datum line (usually the central longitudinal line) is measured first; transverse sections link the parallel lines to it and place every line on a common coordinate frame. The union-jack layout adds centre lines to the diagonals for more crossings. At each crossing the two lines give two values whose difference is the closure error, a check of consistency.
Preparation
Draw the grid with row and column spacing equal to, or an integer multiple of, the base span. Fix the datum line and connection order so that every parallel line links to the datum through at least one transverse section. Clean the surface, measure the span and confirm adequate return light on the longest line.
Workflow diagram
Procedure
- Plan row and column spacing as integer multiples of the span; number the stations and fix the datum line and direction of every line.
- Measure and integrate the datum line, then measure the parallel lines station by station.
- Measure transverse sections that link each parallel line to the datum to obtain its start height.
- Shift every line by its link result to build unified grid heights.
- Compute closure errors at all crossings; re-check outliers on site and handle unresolvable residuals statistically with full documentation.
- Evaluate flatness against the agreed reference and report closure distribution, method and uncertainty.
Calculation
Line integration follows straightness: Δh=L·tan(θ″·π/648000), accumulated per segment. The start height of line k comes from its link section and shifts the whole line: zk,i′=zk,i+h0,k. Closure at a crossing is c=zA−zB and all closures should be of similar magnitude; flatness is evaluated on the unified data with the agreed reference.
Illustrative example
Teaching data, not measured: a 600 mm × 400 mm plate with a 100 mm span and four longitudinal lines of five points. If the datum line ends at +1.9 μm and a linked parallel line starts at +0.7 μm after shifting, its closures are +0.2 μm and −0.1 μm. An example minimum-zone value on the unified data is 3.2 μm; no real part is implied.
Limitations
- A transverse section linking only one line provides no closure check.
- Large closures indicate local reading faults; simple averaging hides the problem.
- Grid results depend on the unification procedure; compare lines only in the common frame.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.