Semiconductor Equipment
Inspection stages, precision XY platforms and equipment mounting surfaces.
Methods
- Precision stage pitch and yaw
- Mounting reference alignment
- Rotary platform angle
- Guideway geometry
Procedure
- Establish stage coordinates
- Verify range and reference
- Sample each position
- Compare repeat runs
- Document the result
Geometric measurements do not by themselves establish lithography overlay or wafer process performance.
Typical measurement scenarios in this industry
Each scenario gives the object, tolerance range and method, ready to take to the selector.
Precision XY stage pitch and yaw
Strokes of 50–300 mm, often 1–5″. Sample every 10–20 mm across the travel and watch periodic components and reversal jumps.
Zhongji fully automatic autocollimators↗Viewport alignment into a vacuum chamber
Measuring through a window adds refraction and figure error. Correct for incidence angle and cross-check against an external reference mirror.
Wide-field electronic autocollimators↗Chuck and wafer-stage flatness
150–300 mm diameter, often 1–3 μm. For small high-precision areas an autocollimator with a short base avoids an interferometer's field limit.
Metrology autocollimator series↗Dual-drive gantry synchronisation and orthogonality
Unequal drives yaw the beam. Two instruments, or one multi-channel unit, read both ends and give yaw and synchronisation error directly.
Zhongji automatic measurement series↗Vibration and repeatability check after installation
Sample one target for 10 min and read peak-to-peak angle noise and spectrum to judge foundation, isolators and air supply.
Zhongji high-speed dynamic autocollimators↗Two-plane straightness acceptance of stage guideways
Granite stage guideways with a few hundred millimetres of travel at 0.5 μm level; read at 50 mm spans and evaluate both planes by minimum zone.
Metrology autocollimator series↗Electrostatic chuck flatness
Chucks Ø 200–300 mm, 1–2 μm; measure at working temperature and clamping.
General-purpose electronic autocollimators↗Lift pin synchronisation and table level
Asynchronous pins slip the wafer; check with displacement sensors or multi-point level.
General-purpose electronic autocollimators↗Recommended instruments


Zhongji high-speed electronic autocollimator accuracy 1″

Zhongji high-speed electronic autocollimator accuracy 2″
Understand the measurement step by step
- 01
Establish stage coordinates
- 02
Verify range and reference
- 03
Sample each position
- 04
Compare repeat runs
- 05
Document the result
- Define Abbe geometry · Define travel direction, angular-channel signs and the effective offset from the measurement line to the point of interest. The 100 mm arm is an assumed example geometry, not a product specification.
- Read two static positions · Read both angular channels at P0 and P1 using the same settling condition, recording temperature and stage state.
- Subtract channel references · Subtract P0 readings separately from each channel to obtain pitch and yaw changes; raw channel zeros are not stage errors.
- Estimate and verify · Project the actual Abbe arm into each direction of interest to estimate position effects. Add a reverse run and a fixed-position time series to separate reversal differences from drift.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Semiconductor stage: angular change and Abbe-arm effects
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project. Pitch and yaw are compared at two static stage positions, then a defined effective 100 mm Abbe arm is used to estimate a directional position effect. This is not measured wafer-overlay or chip-inspection performance.
Setup and preparation
Define travel direction, angular-channel signs and the effective offset from the measurement line to the point of interest. The 100 mm arm is an assumed example geometry, not a product specification.
Read both angular channels at P0 and P1 using the same settling condition, recording temperature and stage state.
Subtract P0 readings separately from each channel to obtain pitch and yaw changes; raw channel zeros are not stage errors.
Project the actual Abbe arm into each direction of interest to estimate position effects. Add a reverse run and a fixed-position time series to separate reversal differences from drift.
Example data and records
P0: pitch +0.10″, yaw −0.10″.
P1: pitch +0.50″, yaw +0.20″.
Illustrative effective arm H=100 mm; its direction and sign must be established separately for each component.
Calculation steps
Changes are Δpitch=0.40″ and Δyaw=0.30″. With e≈Hθrad, a 100 mm arm gives directional effects of approximately 0.193925 μm and 0.145444 μm.
Interpretation
These are separate directional components for a specified geometry. They cannot simply be added as overlay error or treated as total stage positioning error.
Verification and pitfalls
Determine the actual Abbe arm and channel mapping from the mechanical measurement model.
Roll and translational errors are excluded from this two-channel angle example.
Static station results do not replace high-speed scan, vibration or process-state verification.