MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / New energy and battery manufacturing
APPLICATION GUIDE

New energy and battery manufacturing

Coating rolls, stacking tables, module fixtures, cell assembly lines and PV modules.

Methods

Procedure

  1. Establish datum
  2. Roll parallelism
  3. Table flatness
  4. Fixture re-check
  5. Line acceptance

Geometric checks do not replace electrical, coating-thickness or weld-strength testing.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗
STEP BY STEP

Understand the measurement step by step

  1. 01

    Establish datum

  2. 02

    Roll parallelism

  3. 03

    Table flatness

  4. 04

    Fixture re-check

  5. 05

    Line acceptance

Principle schematic · not to scale
1 / 5
  1. Establish datum
  2. Roll parallelism
  3. Table flatness
  4. Fixture re-check
  5. Line acceptance

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Geometric control path on a battery-module line

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching note: stack assembly, coating and welding fixtures are sensitive to flatness, parallelism and positioning, while line takt demands fast, traceable in-line checks.

Setup and preparation

  • Split the need by station: roller parallelism, stack-platform flatness, weld-fixture location, module outline.

  • Give every station one reproducible datum and one acceptable takt; do not move a metrology-lab setup onto the line.

  • Place offline re-checks after changeover, roller change or fixture repair, not on a calendar.

  • Keep raw angle or displacement readings, not just pass/fail flags.

Interpretation

The payoff shows up as scrap rate and changeover time, not as a single precision figure.

Verification and pitfalls

  • Under takt pressure, settling and cleaning are the first steps dropped — both bias results.

  • Verify in-line gauges with a reference artefact and archive the record with production data.

Why this method

Most error comes from heat and clamping, not from instrument resolution; fix datum and thermal state first.

Evaluation boundary

Acceptance follows the agreed measurement plan and sampling rate; one good part is not a batch result.